BGR-022365模塊,ADVANTEST使用速度
降壓電路經(jīng)LED接入零線和火線,由于LED內(nèi)部等效一個(gè)電容并聯(lián)一個(gè)電阻負(fù)載,相當(dāng)于一個(gè)電阻串聯(lián)在母線上,降壓電路正常工作給后端控制系統(tǒng)供電。在關(guān)態(tài)時(shí),需要重點(diǎn)關(guān)注LED是否存在“鬼火”現(xiàn)象(LED微亮)。
“鬼火”現(xiàn)象出現(xiàn)的原因?yàn)椋河捎贚ED與降壓電路串聯(lián)在零火線之間,當(dāng)降壓電路需要的輸入電流過(guò)大,則流進(jìn)LED的電流同樣增大,就會(huì)導(dǎo)致LED短暫工作,出現(xiàn)微亮現(xiàn)象。

BGR-022365模塊,ADVANTEST使用速度針對(duì)該問(wèn)題,市面上已有部分廠家能把單火線電源的待機(jī)功耗做到幾個(gè)毫瓦。參考金升陽(yáng)的非隔離LSF01-K5BxxSS系列,該產(chǎn)品結(jié)合外圍電路可滿足全球輸入電壓范圍(85-264VAC),在這輸入工作電壓范圍內(nèi)能維持超低待機(jī)功耗,穩(wěn)定輸出電壓5V、12V等,其待機(jī)功耗約為5.2mW
圖片要點(diǎn)二、關(guān)注單火線電源應(yīng)用電路的功耗問(wèn)題
如何平衡取電能力和不能頻閃,常見(jiàn)的解決方式為有可控硅和繼電器兩種方案。由于可控硅發(fā)熱問(wèn)題,繼電器方案目前在市面上較為主流,以下主要講解繼電器方案的工作原理。其開(kāi)態(tài)的具體工作原理如圖8所示。
1、零火線兩端電壓為正弦波,當(dāng)交流電在正半波時(shí),由于二極管D2的單向?qū)щ娦院蚆OS管Q1斷開(kāi),此時(shí)的電流流經(jīng)二極管D1、儲(chǔ)能和控制電路,使儲(chǔ)能和控制電路工作,提供穩(wěn)定輸出電壓給后端控制系統(tǒng)工作,同時(shí)在某個(gè)設(shè)定電壓時(shí)控制MOS管Q1導(dǎo)通。故交流電在正半波時(shí),只有一小部分能量?jī)?chǔ)存下來(lái)給后端控制系統(tǒng)供電,剩余能量通過(guò)MOS管Q1給LED供電。
2、當(dāng)交流電在負(fù)半波時(shí),此時(shí)電流通過(guò)LED和二極管D2形成回路,給LED供電。單火線電源應(yīng)用時(shí)應(yīng)注意兩點(diǎn):
1、LED燈功率不宜過(guò)小,若LED燈功率過(guò)小,會(huì)導(dǎo)致開(kāi)態(tài)取電電路無(wú)法儲(chǔ)存能量給后級(jí)電路供電,能使用的最小LED燈功率需要結(jié)合不同的電路和器件參數(shù)決定;
2、控制電路工作功耗不宜過(guò)大,若控制電路工作功耗過(guò)大,則會(huì)導(dǎo)致關(guān)態(tài)出現(xiàn)“鬼火”現(xiàn)象和開(kāi)態(tài)取電電路異常,由于開(kāi)態(tài)取電電路在參數(shù)確定的情況下,單個(gè)周期儲(chǔ)存的能量有限,無(wú)法提供充足的能量給工作功耗過(guò)大的控制電路;若實(shí)際應(yīng)用需要工作功耗大的控制電路,則需要另外搭建電路解決該問(wèn)題。
單火線的可靠性、體積、應(yīng)用電路成為重點(diǎn)關(guān)注要素
recommends using powerful cam profile function to upgrade each rotation through Kobelco special software. The integrated motion solution realizes the positioning cam and the continuous cam profile change on the flywheel.
By implementing the Rockwell Automation integrated architecture control solution, Kobelco reduced cabling time by 20%, installation time by 30% and development time by 40%. The company has achieved high efficiency in integration and startup, load control and grinding control.
For example, rslogix 5000 software is very easy to learn and use. Its modular program architecture and clear motion processing function make it easy to manage applications, repeat practicality, debug and diagnose, thus accelerating the supply speed of equipment. In addition, Rockwell automatic positioning torque solution improves the benchmark performance by 60% (load control change +/-18n), and it can be completed in 3 seconds. Moreover, for grinding control, the positioning cam brings high accuracy grinding, which reduces the overall grinding time compared with the previous method. The controller, remote IO with dh+ bus, has been phased out because PLC5 is an early product of ab. its spare parts are difficult to buy and the price is high, which increases the maintenance cost of the equipment.