HONEYWELL SPS5785脈沖模塊
計(jì)量、操作和報(bào)警通過單擊計(jì)量按鈕或單擊可查看計(jì)量、操作和報(bào)警屏幕菜單欄上的屏幕并單擊計(jì)量/操作。計(jì)量上顯示的信息,通過在查看屏幕時(shí)單擊計(jì)量按鈕,或通過以下方式凍結(jié)操作和報(bào)警屏幕:單擊菜單欄上的測光,然后單擊禁用測光??赏ㄟ^單擊恢復(fù)計(jì)量按鈕,或單擊菜單欄上的計(jì)量并單擊啟用計(jì)量。計(jì)量,操作和報(bào)警屏幕由兩個(gè)選項(xiàng)卡組成:操作和報(bào)警/狀態(tài)。操作標(biāo)號操作選項(xiàng)卡計(jì)量值、設(shè)定值和控制功能如圖5-16所示。發(fā)電機(jī)電壓(V)。這些計(jì)量值報(bào)告了VA-B、VC-B、VCA和VAVG發(fā)電機(jī)的狀態(tài)電壓。報(bào)告的值是在端子E1、E2和E3處感測到的電壓與發(fā)電機(jī)PT比。所有計(jì)量值每秒更新一次。當(dāng)單相感應(yīng)為使用(系統(tǒng)配置屏幕、感測電壓)和DECS-100感測電壓端子(E1,E2和E3)如圖4-7或4-9所示連接,所有發(fā)電機(jī)電壓計(jì)量值將是相同的。運(yùn)行狀態(tài)。操作狀態(tài)控制和指示器包括三個(gè)按鈕和三個(gè)相應(yīng)的指標(biāo)。
操作狀態(tài)按鈕標(biāo)記為PF、VAR和OFF
單擊PF按鈕將相鄰PF指示器的顏色更改為綠色,并使DECS-100保持期望功率因數(shù)調(diào)節(jié)點(diǎn)。功率因數(shù)調(diào)節(jié)點(diǎn)可設(shè)置在0.6范圍內(nèi)導(dǎo)致0.6滯后。單擊VAR按鈕將相鄰VAR指示器的顏色更改為綠色,并使DECS-100保持期望的var調(diào)節(jié)點(diǎn)。可以設(shè)置無功調(diào)節(jié)點(diǎn)在100%吸收到100%生成的范圍內(nèi)。單擊“關(guān)閉”按鈕可更改相鄰關(guān)閉指示器的顏色為紅色,并禁用功率因數(shù)和無功調(diào)節(jié)。工作狀態(tài)控制裝置的操作由跨接觸點(diǎn)的狀態(tài)決定DECS-100 Var/PF控制端子(52J、52K)。當(dāng)這些觸點(diǎn)打開時(shí),工作狀態(tài)控件已啟用。閉合端子52J和52K處的觸點(diǎn)將禁用工作狀態(tài)控制和中斷VAR或功率因數(shù)的調(diào)節(jié),直到觸點(diǎn)再次打開。
設(shè)定值-電壓(V)。該設(shè)置字段可用于輸入所需的發(fā)電機(jī)輸出端子電壓電壓設(shè)定值也可以在設(shè)置調(diào)整屏幕、設(shè)定值選項(xiàng)卡、或其他位置輸入,自動電壓調(diào)節(jié)器(AVR)-AVR設(shè)定點(diǎn)(V)。以下情況下,此字段的背景色為綠色:在AVR模式下運(yùn)行,功率因數(shù)和無功調(diào)節(jié)被禁用。設(shè)定值-電流(A)。該設(shè)置定義了在FCR模式下運(yùn)行時(shí)的磁場電流設(shè)定值。這個(gè)電流設(shè)定值也可在設(shè)置調(diào)整屏幕、設(shè)定值選項(xiàng)卡、現(xiàn)場電流中輸入調(diào)節(jié)器(FCR)-FCR設(shè)定點(diǎn)??梢砸?.01的增量輸入0到7 Adc的電流值A(chǔ)dc。在FCR模式下操作時(shí),該字段的背景顏色為綠色。
Operating Status. The Operating Status controls and indicators include three buttons and three corresponding indicators. Operating Status buttons are labeled PF, VAR, and OFF. Clicking the PF button changes the color of the adjacent PF indicator to green and causes the DECS-100 to maintain the desired power factor regulation point. The power factor regulation point can be set within the range of 0.6 lead to 0.6 lag. Clicking the VAR button changes the color of the adjacent VAR indicator to green and causes the DECS-100 to maintain the desired var regulation point. The var regulation point can be set within the range of 100 percent absorb to 100 percent generate. Clicking the OFF button changes the color of the adjacent OFF indicator to red and disables power factor and var regulation. Operation of the Operating Status controls is determined by the status of the contacts connected across the DECS-100 Var/PF Control terminals (52J, 52K). When these contacts are open, the Operating Status controls are enabled. Closing the contacts at terminals 52J and 52K disables the Operating Status controls and interrupts regulation of vars or power factor until the contacts are opened again. Setpoint - Voltage (V). This setting field can be used to enter the desired generator output terminal voltage. The voltage setpoint can also be entered at the Setting Adjustments screen, Setpoint tab, Automatic Voltage Regulator (AVR) - AVR Setpoint (V). The background color of this field is green when operating in AVR mode and power factor and var regulation is disabled. Setpoint - Current (A). This setting defines the field current setpoint when operating in FCR mode. The current setpoint can also be entered at the Setting Adjustments screen, Setpoint tab, Field Current Regulator (FCR) - FCR Setpoint. Current values from 0 to 7 Adc may be entered in increments of 0.01 Adc. The background color of this field is green when operating in FCR mode.