產(chǎn)品內(nèi)容介紹
A-B 80156-815-54-R用于IGCT可控硅
設(shè)置網(wǎng)頁訪問通過使用Web瀏覽器訪問為選項(xiàng)模塊設(shè)置的IP地址,您可以查看選項(xiàng)模塊網(wǎng)頁以獲取有關(guān)模塊、驅(qū)動(dòng)器和其他連接到驅(qū)動(dòng)器的DPI設(shè)備,如HIM或轉(zhuǎn)換器。默認(rèn)情況下,選項(xiàng)模塊網(wǎng)頁處于禁用狀態(tài)。啟用該選項(xiàng)模塊網(wǎng)頁,將設(shè)備參數(shù)26-[web Enable]設(shè)置為“1”(已啟用)。
有關(guān)選項(xiàng)模塊網(wǎng)頁的更多詳細(xì)信息,請(qǐng)參閱第8章“查看”選項(xiàng)模塊網(wǎng)頁。
在適配器模式下,選項(xiàng)模塊可以配置為在發(fā)生選定驅(qū)動(dòng)器故障和/或清除,和/或當(dāng)選項(xiàng)模塊出現(xiàn)通信或空閑故障時(shí)行動(dòng)設(shè)備參數(shù)27的位0-[Web Features]用于保護(hù)配置的電子郵件設(shè)置。默認(rèn)情況下,設(shè)置不受保護(hù),用戶可以進(jìn)行更改。要保護(hù)配置的設(shè)置,請(qǐng)?jiān)O(shè)置E-mail-Cfg的值位0至“0”(禁用)。
您可以通過更改位0取消保護(hù)配置返回“1”(啟用)。電子郵件將始終保持活動(dòng)狀態(tài),無論其設(shè)置是否受保護(hù),除非從未發(fā)送過電子郵件已配置。有關(guān)配置選項(xiàng)模塊的詳細(xì)信息,請(qǐng)發(fā)送電子郵件消息或停止電子郵件
請(qǐng)參閱適配器模式配置電子郵件通知網(wǎng)頁,第130頁。
位0是最右邊的位。在上例中,它等于“1”(啟用)。對(duì)此參數(shù)的更改將立即生效。不需要重置。
重要信息根據(jù)所選的操作模式(適配器或抽頭),選項(xiàng)模塊提供了一組具有不同信息的獨(dú)特網(wǎng)頁。重置選項(xiàng)模塊更改為開關(guān)和跳線設(shè)置以及一些選項(xiàng)模塊參數(shù)要求您在新設(shè)置生效之前重置選項(xiàng)模塊。你可以通過重啟驅(qū)動(dòng)器或使用設(shè)備重置選項(xiàng)模塊參數(shù)25-[重置模塊]。
將設(shè)備參數(shù)25-[重置模塊]設(shè)置為“1”(重置模塊)。
當(dāng)您輸入“1”(重置模塊)時(shí),選項(xiàng)模塊將立即重置。重置模塊的另一種方法是重啟驅(qū)動(dòng)器。
當(dāng)您輸入“2”(設(shè)置默認(rèn)值)時(shí),選項(xiàng)模塊將設(shè)置其所有設(shè)備和主機(jī)參數(shù)的出廠默認(rèn)值。(這與按使用中描述的MEMORY文件夾方法時(shí)使用ALL軟鍵第50頁將選項(xiàng)模塊參數(shù)恢復(fù)為出廠默認(rèn)值。)之后執(zhí)行“設(shè)置默認(rèn)值”時(shí),必須輸入“1”(重置模塊)或重啟驅(qū)動(dòng)以使新值生效。此后,將恢復(fù)此參數(shù)值為“0”(就緒)。
注意:存在受傷或設(shè)備損壞的風(fēng)險(xiǎn)。如果選項(xiàng)模塊是將控制I/O傳輸?shù)津?qū)動(dòng)器,當(dāng)您重置選項(xiàng)模塊。在重置選項(xiàng)模塊。
重要信息:在分接模式下操作選項(xiàng)模塊時(shí),主機(jī)參數(shù)不是支持,因此只有設(shè)備參數(shù)重置為其出廠默認(rèn)值。
重要信息:執(zhí)行設(shè)置默認(rèn)值時(shí),驅(qū)動(dòng)器可能會(huì)檢測(cè)到?jīng)_突,然后不會(huì)允許此功能發(fā)生。如果發(fā)生這種情況,首先解決沖突,然后重復(fù)“設(shè)置默認(rèn)值”操作。沖突的常見原因包括驅(qū)動(dòng)器正在運(yùn)行或控制器處于運(yùn)行模式。
Setting Web Page Access
By using a web browser to access the IP address set for the option module, you can view the option module web pages for information about the module, the drive and other DPI devices connected to the drive, such as HIMs or converters. By default, the option module web pages are disabled. To enable the option module web pages, set Device Parameter 26 - [Web Enable] to “1” (Enabled). For more details on the option module web pages, see Chapter 8, Viewing Option Module Web Pages. In Adapter mode, the option module can be configured to automatically send email messages to desired addresses when selected drive faults occur and/or are cleared, and/or when the option module takes a communication or idle fault action. Bit 0 of Device Parameter 27 - [Web Features] is used to protect the configured settings for e-mail messaging. By default, settings are not protected and the user can make changes. To protect the configured settings, set the value of E-mail Cfg Bit 0 to “0” (Disabled). You can unprotect the configuration by changing Bit 0 back to “1” (Enabled). E-mail messaging will always remain active regardless of whether or not its settings are protected—unless e-mail messaging was never configured. For more information about configuring option module e-mail messaging or to stop e-mail messages, see Adapter Mode Configure E-mail Notification Web Page on page 130. Bit 0 is the right-most bit. In the example above, it equals “1” (Enabled). Changes to this parameter take effect immediately. A reset is not required. IMPORTANT Depending on its selected operating mode (Adapter or Tap), the option module provides a unique set of web pages with different information.
Resetting the Option Module
Changes to switch and jumper settings and some option module parameters require you to reset the option module before the new settings take effect. You can reset the option module by power cycling the drive or by using Device Parameter 25 - [Reset Module]. Set Device Parameter 25 - [Reset Module] to “1” (Reset Module). When you enter “1” (Reset Module), the option module will be immediately reset. An alternate method to reset the module is by power cycling the drive. When you enter “2” (Set Defaults), the option module will set ALL of its Device and Host parameters to their factory default values. (This is the same as pressing the ALL soft key when using the MEMORY folder method described in Restoring Option Module Parameters to Factory Defaults on page 50.) After performing a Set Defaults, you must enter “1” (Reset Module) or power cycle the drive so that the new values take effect. Thereafter, this parameter will be restored to a value of “0” (Ready). ATTENTION: Risk of injury or equipment damage exists. If the option module is transmitting control I/O to the drive, the drive may fault when you reset the option module. Determine how your drive will respond before resetting the option module. IMPORTANT When operating the option module in Tap mode, Host parameters are NOT supported, so only Device parameters are reset to their factory default values. IMPORTANT When performing a Set Defaults, the drive may detect a conflict and then not allow this function to occur. If this happens, first resolve the conflict and then repeat a Set Defaults action. Common reasons for a conflict include the drive running or a controller in Run mode.


公司主營(yíng)產(chǎn)品圖展示