A4H254-8F8T P0973JP模擬量輸出模塊
關(guān)閉電源
鎖定/掛牌裝置;并等待五分鐘以使所有電壓放電。打開電源結(jié)構(gòu)的托架門。更換隔離板1.使用儀表測試交流線路、直流母線和隔離板上端子的電壓。2.戴上ESD腕帶并將其連接到PE母線(裝置底部的后接地棒)。3.拆卸Lexan? 與隔離板隔離。4.斷開P1的接地連接、J1的反饋連接、J2的帶狀電纜以及J7的電流傳感器連接(如圖1所示)。5.斷開接線板TB5和TB6。6.逆時(shí)針轉(zhuǎn)動(dòng)六個(gè)安裝支架,松開電路板并將電路板拉出。7.從每個(gè)接線板上拆下負(fù)載電阻器。8.將隔離板放在防靜電袋中!注意:如果存在任何電壓,請(qǐng)拆下電壓源。繼續(xù)下一步前,再次檢查電壓。
負(fù)載電阻器套件
TB2僅用于B系列RGU(或RGU至交流線路至直流母線至主控制板(J12)至未使用的電流傳感器T相負(fù)載電阻器(F17、F18、F19)S相負(fù)載電阻器*R相負(fù)載電阻器至控制電路電路。電流代碼電壓代碼負(fù)載電阻器套件編號(hào)歐姆%公差類型J N,電流電壓系列代碼位于主控制板附近的典型RGU銘牌例如,此銘牌顯示電流代碼L和電壓代碼C。合適的套件為2364-SDP06A。由于銘牌顯示這是一個(gè)a系列裝置,TB2中不需要電阻器。a系列B出版物2364F-5.13 1999年6月RGU? 隔離板更換5安裝隔離板1.將負(fù)載電阻器固定在新板上的端子中(驗(yàn)證透明絕緣層沒有進(jìn)入端子)。擰緊至6 lb in(0.7 N-m)。注:TB2僅用于B系列RGU(見數(shù)據(jù)銘牌)。2.將電路板放在六個(gè)支架上并固定電路板。3.將端子塊TB5和TB6連接至隔離板。接線板必須牢固地壓入適當(dāng)?shù)牟遄小?.將反饋連接連接到J1,將帶狀電纜連接到J2,將電流傳感器連接到J7,將PE地線連接到P1
Turn off the power
Lock out/tag out device; Wait five minutes to discharge all voltages. Open the bay door of the power structure. Replace the isolation board 1. Use the instrument to test the voltage of AC lines, DC buses and terminals on the isolation board. 2. Wear the ESD wrist strap and connect it to the PE bus (the rear ground bar at the bottom of the unit). 3. Remove Lexan ? Isolate from the isolation plate. 4. Disconnect P1's grounding connection, J1's feedback connection, J2's ribbon cable and J7's current sensor connection (as shown in Figure 1). 5. Disconnect terminal blocks TB5 and TB6. 6. Rotate the six mounting brackets anticlockwise, release the circuit board and pull it out. 7. Remove the load resistor from each terminal block. 8. Put the isolation plate in the anti-static bag! NOTE: If any voltage is present, remove the voltage source. Check the voltage again before proceeding to the next step.
KIT-LOAD RESISTOR
TB2 is only used for B series RGU (or RGU to AC line to DC bus to main control board (J12) to unused current sensor T phase load resistor (F17, F18, F19) S phase load resistor * R phase load resistor to control circuit circuit. Current Code Voltage Code Load Resistor Kit Number Ohm% Tolerance Type J N, Current Voltage Series Code Typical RGU nameplate located near the main control panel For example, this nameplate shows current code L and voltage code C. The appropriate kit is 2364-SDP06A. Since the nameplate shows that this is a series a device, no resistor is required in TB2. A Series B Publication 2364F-5.13 June 1999 RGU ? Replace the isolation board 5 Install the isolation board 1. Fix the load resistor in the terminal on the new board (verify that the transparent insulating layer does not enter the terminal). Tighten to 6 lb in (0.7 N-m). Note: TB2 is only used for B series RGUs (see data nameplate). 2. Place the circuit board on the six brackets and fix the circuit board. 3. Connect terminal blocks TB5 and TB6 to the isolation board. The terminal block must be firmly pressed into the appropriate socket. 4. Connect the feedback connection to J1, the ribbon cable to J2, the current sensor to J7, and the PE ground wire to P1