HONEYWELL CC-TAON11自動(dòng)化模塊備件
t例如玻璃瓶。探頭可由輸入開關(guān)電源的+24 V供電。NPN晶體管的輸出可以被帶到配置為計(jì)數(shù)器的可分配數(shù)字輸入之一。n ASSIGNABLE INPUT 1 n[ENTER]了解更多INPUT 1 FUNCTION:數(shù)字計(jì)數(shù)器范圍:見上文。只有當(dāng)輸入1(4)功能為“數(shù)字計(jì)數(shù)器”時(shí),以下設(shè)置點(diǎn)才適用。計(jì)數(shù)器單位:?jiǎn)挝环秶?個(gè)字母數(shù)字字符。僅當(dāng)INPUT 1(4)FUNCTION為“數(shù)字計(jì)數(shù)器”Counter PRESET VALUE:0范圍:0到1000000000,步長(zhǎng)為1時(shí)才可見。僅當(dāng)輸入1(4)功能為“數(shù)字計(jì)數(shù)器”計(jì)數(shù)器類型:遞增范圍:遞增、遞減時(shí)才可見。僅當(dāng)輸入1(4)功能為“數(shù)字計(jì)數(shù)器”計(jì)數(shù)器報(bào)警:關(guān)閉范圍:關(guān)閉、鎖定、未鎖定時(shí)才可見。僅當(dāng)輸入1(4)功能為“數(shù)字計(jì)數(shù)器”時(shí)才可見,分配報(bào)警繼電器:報(bào)警范圍:報(bào)警、報(bào)警和輔助2、報(bào)警和輔2、報(bào)警與輔助3、報(bào)警與輔3、輔助2、輔助2和輔助3、輔助3。僅當(dāng)輸入1(4)功能為“數(shù)字計(jì)數(shù)器”計(jì)數(shù)器報(bào)警級(jí)別:100范圍:0至1000000000,步長(zhǎng)為1時(shí)才可見。僅當(dāng)輸入1(4)功能為“數(shù)字計(jì)數(shù)器”計(jì)數(shù)器報(bào)警拾?。撼龇秶撼^、低于時(shí)才可見。僅當(dāng)輸入1(4)功能為“數(shù)字計(jì)數(shù)器”計(jì)數(shù)器報(bào)警事件:關(guān)閉范圍:開、關(guān)時(shí)才可見。僅當(dāng)輸入1(4)功能為“數(shù)字計(jì)數(shù)器”時(shí),才顯示ENTER ESCAPE(輸入ESCAPE)輸入ESCAPE(輸出ESCAPE信息)輸入ESCCAPE(輸出ESCAP信息)輸入ESCAPE(輸出ESCAPE信息對(duì)于其中一個(gè)可分配的數(shù)字輸入,此處顯示的設(shè)置點(diǎn)消息將跟隨分配消息。測(cè)量每個(gè)開關(guān)閉合之間的時(shí)間段,并根據(jù)每轉(zhuǎn)一次閉合轉(zhuǎn)換為RPM值。可以配置跳閘和警報(bào),使得電機(jī)或負(fù)載必須在電機(jī)啟動(dòng)開始后的設(shè)定時(shí)間段內(nèi)處于一定速度。電機(jī)停止時(shí),轉(zhuǎn)速計(jì)跳閘和報(bào)警被忽略。RPM值可與A2 METERING?SPEED?轉(zhuǎn)速表實(shí)際值一起查看。例如,感應(yīng)接近探頭或霍爾效應(yīng)齒輪齒傳感器可用于感應(yīng)電機(jī)上的鑰匙。探頭可由輸入開關(guān)電源的+24 V供電。NPN晶體管輸出可被帶到配置為轉(zhuǎn)速表的可分配開關(guān)輸入之一。n ASSIGNABLE INPUT 1 n[ENTER]了解更多輸入1功能:轉(zhuǎn)速表范圍:見上文。只有當(dāng)輸入1(4)功能為“轉(zhuǎn)速計(jì)”時(shí),以下設(shè)定點(diǎn)才適用。額定轉(zhuǎn)速:3600 RPM范圍:100至7200 RPM,步長(zhǎng)為1。僅當(dāng)輸入1(4)功能為“轉(zhuǎn)速表”轉(zhuǎn)速表報(bào)警:關(guān)閉范圍:關(guān)閉、鎖定、未鎖定時(shí)才可見。僅當(dāng)輸入1(4)功能為“轉(zhuǎn)速計(jì)”時(shí)可見,分配報(bào)警繼電器:報(bào)警范圍:報(bào)警、報(bào)警和輔助2、報(bào)警和輔2和輔3、報(bào)警和副3、輔助2、輔助2和輔助3、輔助3。僅當(dāng)輸入1(4)功能為“轉(zhuǎn)速計(jì)”轉(zhuǎn)速計(jì)報(bào)警速度:10%額定范圍:5至100%,步長(zhǎng)為1時(shí)可見。僅當(dāng)輸入1(4)功能為“轉(zhuǎn)速表”轉(zhuǎn)速表報(bào)警延遲:1 s范圍:1到250 s,步長(zhǎng)為1。僅當(dāng)輸入1(4)功能為“轉(zhuǎn)速計(jì)”轉(zhuǎn)速計(jì)報(bào)警事件:關(guān)閉范圍:開、關(guān)時(shí)可見。僅當(dāng)輸入2(4)函數(shù)為“轉(zhuǎn)速表”轉(zhuǎn)速計(jì)跳閘:關(guān)閉范圍,鎖定,未鎖定時(shí)可見。僅當(dāng)輸入1(4)功能為“轉(zhuǎn)速計(jì)”時(shí)才可見,指定跳閘繼電器:跳閘范圍:跳閘、跳閘和輔助2、跳閘與輔助2和輔助3、跳閘與輔3。僅當(dāng)輸入1(4)功能為“轉(zhuǎn)速表”轉(zhuǎn)速表跳閘速度:10%額定范圍:5至95%,步長(zhǎng)為1。僅當(dāng)輸入1(4)功能為“轉(zhuǎn)速表”轉(zhuǎn)速表跳閘延遲:1 s范圍:1到250 s,步長(zhǎng)為1。僅當(dāng)輸入1(4)功能為“轉(zhuǎn)速計(jì)”時(shí)才可見,輸入ESCAPE(轉(zhuǎn)速計(jì))ENTER ESCAPE?信息ESCAPE MESSAGE ESCAPE ESCAPE MESSAGE ESCAPE MESTAGE ESCAPEMESSAGE ESCAPE ESCAP MESSAGE(轉(zhuǎn)速表)MESSAGE ESC APE ESCAPE MESSAGE DESSAGE ESCAP(轉(zhuǎn)速計(jì)功能)輸入ESCAPE-ESCAPE信息ESCAPEMISSAGE ESCCAPE(轉(zhuǎn)速傳感器)MESSAG ESCAPE ESCAPE MESPAGE ESCAPES ESCAPE RESSAGE ESCRAPE ESCAPE-MESSAGE信息ESCAP(速度計(jì))功能4-24 469電機(jī)管理繼電器GE Multilin 4.4 S3數(shù)字輸入4設(shè)定點(diǎn)是可分配給四個(gè)可分配數(shù)字輸入中的任何一個(gè)的四個(gè)通用開關(guān)功能。一旦為其中一個(gè)數(shù)字輸入選擇了通用開關(guān)功能,此處顯示的設(shè)置點(diǎn)消息將跟隨分配消息。然后可以為該輸入配置警報(bào)和/或跳閘。如果需要,可為警報(bào)和/或跳閘分配一個(gè)通用名稱和一個(gè)從電機(jī)啟動(dòng)開始的通用阻斷時(shí)間(如果在電機(jī)啟動(dòng)后一段時(shí)間內(nèi)禁用警報(bào))。BLOCK的值為“0”
hat are passing by on a conveyor, glass bottles for instance. The probe could be powered from the +24 V from the input switch power supply. The NPN transistor output could be taken to one of the assignable digital inputs configured as a counter. n ASSIGNABLE INPUT 1 n [ENTER] for more INPUT 1 FUNCTION: Digital Counter Range: See above. The following setpoints apply only if INPUT 1(4) FUNCTION is “Digital Counter”. COUNTER UNITS: Units Range: 6 alphanumeric characters. Only seen if INPUT 1(4) FUNCTION is “Digital Counter” COUNTER PRESET VALUE: 0 Range: 0 to 1000000000 in steps of 1. Only seen if INPUT 1(4) FUNCTION is “Digital Counter” COUNTER TYPE: Increment Range: Increment, Decrement. Only seen if INPUT 1(4) FUNCTION is “Digital Counter” COUNTER ALARM: Off Range: Off, Latched, Unlatched. Only seen if INPUT 1(4) FUNCTION is “Digital Counter” ASSIGN ALARM RELAYS: Alarm Range: Alarm, Alarm & Auxiliary2, Alarm & Aux2 & Aux3, Alarm & Auxiliary3, Auxiliary2, Aux2 & Aux3, Auxiliary3. Only seen if INPUT 1(4) FUNCTION is “Digital Counter” COUNTER ALARM LEVEL: 100 Range: 0 to 1000000000 in steps of 1. Only seen if INPUT 1(4) FUNCTION is “Digital Counter” COUNTER ALARM PICKUP: Over Range: Over, Under. Only seen if INPUT 1(4) FUNCTION is “Digital Counter” COUNTER ALARM EVENTS: Off Range: On, Off. Only seen if INPUT 1(4) FUNCTION is “Digital Counter” ENTER ESCAPE e e MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE GE Multilin 469 Motor Management Relay 4-23 4 SETPOINTS 4.4 S3 DIGITAL INPUTS 4 k) TACHOMETER PATH: SETPOINTS ?× S3 DIGITAL INPUTS ?× ASSIGNABLE INPUT 1(4) Once the tachometer function is chosen for one of the assignable digital inputs, the setpoint messages shown here will follow the assignment message. The period of time between each switch closure measured and converted to an RPM value based on one closure per revolution. A trip and alarm may be configured such that the motor or load must be at a certain speed within a set period of time from the initiation of motor starting. The tachometer trip and alarm are ignored while the motor is stopped. The RPM value may be viewed with the A2 METERING ?× SPEED ? TACHOMETER actual value. For example, an inductive proximity probe or hall effect gear tooth sensor may be used to sense the key on the motor. The probe could be powered from the +24 V from the input switch power supply. The NPN transistor output could be taken to one of the assignable switch inputs configured as a tachometer. n ASSIGNABLE INPUT 1 n [ENTER] for more INPUT 1 FUNCTION: Tachometer Range: See above. The following setpoints apply only if INPUT 1(4) FUNCTION is “Tachometer”. RATED SPEED: 3600 RPM Range: 100 to 7200 RPM in steps of 1. Only seen if INPUT 1(4) FUNCTION is “Tachometer” TACHOMETER ALARM: Off Range: Off, Latched, Unlatched. Only seen if INPUT 1(4) FUNCTION is “Tachometer” ASSIGN ALARM RELAYS: Alarm Range: Alarm, Alarm & Auxiliary2, Alarm & Aux2 & Aux3, Alarm & Auxiliary3, Auxiliary2, Aux2 & Aux3, Auxiliary3. Only seen if INPUT 1(4) FUNCTION is “Tachometer” TACHOMETER ALARM SPEED: 10% Rated Range: 5 to 100% in steps of 1. Only seen if INPUT 1(4) FUNCTION is “Tachometer” TACHOMETER ALARM DELAY: 1 s Range: 1 to 250 s in steps of 1. Only seen if INPUT 1(4) FUNCTION is “Tachometer” TACHOMETER ALARM EVENTS: Off Range: On, Off. Only seen if INPUT 1(4) FUNCTION is “Tachometer” TACHOMETER TRIP: Off Range: Off, Latched, Unlatched. Only seen if INPUT 1(4) FUNCTION is “Tachometer” ASSIGN TRIP RELAYS: Trip Range: Trip, Trip & Auxiliary2, Trip & Aux2 & Aux3, Trip & Auxiliary3. Only seen if INPUT 1(4) FUNCTION is “Tachometer” TACHOMETER TRIP SPEED: 10% Rated Range: 5 to 95% in steps of 1. Only seen if INPUT 1(4) FUNCTION is “Tachometer” TACHOMETER TRIP DELAY: 1 s Range: 1 to 250 s in steps of 1. Only seen if INPUT 1(4) FUNCTION is “Tachometer” ENTER ESCAPE e e MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE 4-24 469 Motor Management Relay GE Multilin 4.4 S3 DIGITAL INPUTS 4 SETPOINTS 4 l) GENERAL SWITCH A to D PATH: SETPOINTS ?× S3 DIGITAL INPUTS ?× ASSIGNABLE INPUT 1(4) There are four General Switch functions assignable to any of the four assignable digital inputs. Once a General Switch function is chosen for one of the digital inputs, the setpoint messages shown here follow the assignment message. An alarm and/or trip may then be configured for that input. The alarm and/or trip may be assigned a common name and a common block time from motor start if required (if the alarm is to be disabled until some period of time after he motor has been started). A value of "0" for the BLOCK