Vibro-meter 200-560-000-016 200-560-101-015 VM600 IOC4T
如果需要,可以增加計(jì)算值以允許更多的非循環(huán)流量。如果總線上有其他主機(jī),則必須在這些其他主機(jī)進(jìn)行循環(huán)和非循環(huán)通信所需的時(shí)間內(nèi)增加計(jì)算值。請參閱這些主機(jī)的配置。在多主機(jī)系統(tǒng)中,所有主機(jī)必須使用相同的TTR值。GAP因子(GAP)此參數(shù)定義GAP維護(hù)周期之間的令牌循環(huán)次數(shù)。當(dāng)前版本的CI854/CI854A始終使用1值,與此處輸入的值無關(guān)。最高站點(diǎn)地址(HSA)此參數(shù)定義PROFIBUS上的最高站點(diǎn)地址。將該參數(shù)設(shè)置為至少為總線上所有主設(shè)備和從設(shè)備配置的最高節(jié)點(diǎn)地址數(shù)。
The calculated value may be increased to allow more acyclic
traffic, if necessary.If there are other masters on the bus, the
calculated value has to be increased for the time these other
masters need for their cyclic and acyclic communication. Refer to
the configuration of these masters.
In a multi-master system all masters must use the same
value for TTR.
GAP factor
(GAP)
This parameter defines the number of token rotations between
GAP maintenance cycles.
The current version of the CI854/CI854A always uses a
value of 1 independent of the value entered here.Highest
station
address
(HSA)
This parameter defines the highest station address on the
PROFIBUS. Set the parameter to at least the highest number of
node addresses configured for all masters and slaves present on
the bus.