ABB運(yùn)動(dòng)控制UNC4611B V2 HIER460378R3的操作
選項(xiàng)模塊的功能包括:
?使用Operating(操作)按鈕選擇的適配器或抽頭操作模式模式跳線(xiàn)(J4)。在適配器模式(默認(rèn))下,選項(xiàng)模塊作為支持星形、線(xiàn)性或設(shè)備級(jí)環(huán)(DLR)網(wǎng)絡(luò)拓?fù)?。僅適用于Tap模式與PowerFlex 755驅(qū)動(dòng)器一起使用時(shí),選項(xiàng)模塊使用ENET3(DEVICE)端口作為連接點(diǎn),用于傳輸“Integrated Motion on”EtherNet/IP網(wǎng)絡(luò)數(shù)據(jù)到PowerFlex 755驅(qū)動(dòng)器的嵌入式EtherNet/IP適配器。
?工業(yè)以太網(wǎng)交換機(jī)和ENET1和ENET2網(wǎng)絡(luò)端口為EtherNet/IP星形、線(xiàn)性或設(shè)備級(jí)環(huán)提供連接(DLR)網(wǎng)絡(luò)拓?fù)洹?/p>

?ENET3(設(shè)備)端口,僅適用于支持傳輸“EtherNet/IP網(wǎng)絡(luò)上的Integrated Motion”該驅(qū)動(dòng)器的數(shù)據(jù)。
?PowerFlex 750系列的嵌入式電子數(shù)據(jù)表(EDS)文件無(wú)需從Rockwell下載EDS文件的驅(qū)動(dòng)器自動(dòng)化網(wǎng)站。而是從選項(xiàng)上載EDS文件模塊,使用RSLinx軟件。
?自動(dòng)設(shè)備配置(ADC),即“RSLogix 5000”軟件,版本20或更高版本,功能“支持自動(dòng)下載配置數(shù)據(jù)。這發(fā)生在Logix控制器之后建立與PowerFlex 750系列的EtherNet/IP網(wǎng)絡(luò)連接驅(qū)動(dòng)器(固件版本4.001或更高版本)及其相關(guān)外圍設(shè)備。
?固定螺釘,用于將模塊固定并接地至驅(qū)動(dòng)器。
?開(kāi)關(guān),用于在接通電源之前設(shè)置網(wǎng)絡(luò)節(jié)點(diǎn)地址或者您可以禁用交換機(jī)并使用BOOTP服務(wù)器動(dòng)態(tài)主機(jī)配置協(xié)議(DHCP)服務(wù)器或選項(xiàng)模塊參數(shù)配置IP地址。
?與配置選項(xiàng)的各種配置工具兼容模塊和主機(jī)驅(qū)動(dòng)器。這些工具包括增強(qiáng)的PowerFlex 7-Class驅(qū)動(dòng)器上的HIM(目錄號(hào)20-HIM-A6或20-HIM-C6S),以及驅(qū)動(dòng)器配置軟件,如DriveExplorer軟件,版本6.01或更高版本,或DriveExecutive軟件5.01或更高版。
?報(bào)告選項(xiàng)模塊和網(wǎng)絡(luò)狀態(tài)的狀態(tài)指示器表達(dá)當(dāng)卸下驅(qū)動(dòng)器蓋時(shí),它們是可見(jiàn)的。
?輸入/輸出中配置參數(shù)的32位數(shù)據(jù)鏈路,以滿(mǎn)足應(yīng)用要求(16個(gè)數(shù)據(jù)鏈路,用于將數(shù)據(jù)從網(wǎng)絡(luò)寫(xiě)入驅(qū)動(dòng)器,和16個(gè)數(shù)據(jù)鏈路,從驅(qū)動(dòng)器向網(wǎng)絡(luò)讀取數(shù)據(jù))。
?顯式消息傳遞支持。
The features of the option module include the following: ? Adapter or Tap mode of operation that is selected by using the Operating Mode Jumper ( J4). In Adapter mode (default), the option module operates as a network communication adapter supporting star, linear or device-level ring (DLR) network topologies. In Tap mode—only intended for use with PowerFlex 755 drives—the option module uses ENET3 (DEVICE) port as a connection point to transfer ‘Integrated Motion on the EtherNet/IP network’ data to the PowerFlex 755 drive’s embedded EtherNet/IP adapter. ? Industrial Ethernet switch, and ENET1 and ENET2 network ports that provide connections for EtherNet/IP star, linear, or device-level ring (DLR) network topologies. ? ENET3 (DEVICE) port—for use with only PowerFlex 755 drives—that supports the transfer of ‘Integrated Motion on the EtherNet/IP network’ data for that drive. ? Embedded electronic data sheet (EDS) files for PowerFlex 750-Series drives that eliminate the need to download an EDS file from the Rockwell Automation website. Instead, the EDS file is uploaded from the option module by using RSLinx software. ? Automatic Device Configuration (ADC), which is an ‘RSLogix 5000 software, version 20 or later, feature’ that supports the automatic download of configuration data. This occurs after the Logix controller establishes an EtherNet/IP network connection to a PowerFlex 750-Series drive (firmware revision 4.001 or later) and its associated peripherals. ? Captive screws to secure and ground the module to the drive. ? Switches to set a network node address before applying power to the drive—or you can disable the switches and use a BOOTP server, a Dynamic Host Configuration Protocol (DHCP) server, or option module parameters to configure the IP address. ? Compatibility with various configuration tools to configure the option module and host drive. The tools include the enhanced PowerFlex 7-Class HIM (catalog number 20-HIM-A6 or 20-HIM-C6S) on the drive, and drive-configuration software, such as DriveExplorer software, version 6.01 or later, or DriveExecutive software, version 5.01 or later. ? Status indicators that report the status of the option module and network communication. They are visible when the drive cover is removed. ? Parameter-configured 32-bit Datalinks in the I/O to meet application requirements (16 Datalinks to write data from the network to the drive, and 16 Datalinks to read data to the network from the drive). ? Explicit Messaging support.